$ 695.00 Ex. GST
Available to back order. ETA will be 1 - 2 weeks.
The Kestrel 5200 provides the same trusted accuracy, reliability, and usability as the original Kestrel 4200 and 4300. With its complete suite of environmental measurements plus special features designed to aid HVAC technicians, construction and agriculture professionals, the Kestrel 5200 outperforms the competition as the most compact and complete environmental meter and data logger for all professional uses.
The Kestrel 5 Series platform adds many new features and options. If you’re familiar with the Kestrel 4200 or 4300, the first thing you’ll notice is the larger, higher-resolution and contrast display and improved font readability. The Kestrel 5 series also includes a built-in dual color backlight, extra-strong polycarbonate lens and AA battery operation and offers optional LiNK iOS and Android wireless connectivity and app support. Like all Kestrel meters, the Kestrel 5200 is drop-proof, dust-proof, waterproof and able to withstand harsh environments without damage – so it can work as hard as you do, wherever you go. A range of carry pouch options makes it even easier to take your Kestrel meter with you.
The Kestrel 5200 offers advanced calculators and readings that are unique in the portable meter market and are designed to make your job easier. In addition to measuring current environmental conditions, the Kestrel 5200 tracks and logs over 10,000 sets of time-stamped data. Your data log can be transferred to a mobile device wirelessly with the LiNK wireless communication option and Kestrel LiNK app, or to a PC/MAC with either the optional Kestrel LiNK Dongle or waterproof USB Data Transfer Cable (available separately).
Kestrels have been put to the test in some of the harshest conditions on the planet. U.S. Special Forces, combat weather teams, wildland firefighters, smoke jumpers, Mt. Everest expeditions and auto pit crews are just a few who rely on a Kestrel to provide them with the crucial environmental data they need. Watch the Weather Channel during a hurricane, and you’re sure to spot a Kestrel in action. Technicians have been purchasing Kestrel meters for their toolboxes for years, knowing they will provide the readings they need immediately and reliably. Construction managers all over the world have relied on their Kestrel meters to ensure work-site safety and cost-effective concrete pours. Farmers that need know a Kestrel meter can help them avoid property damage and maximize productivity.
Measures:| ACCURACY | RESOLUTION | SPECIFICATION RANGE | |
| Wind Speed | Air Speed | Larger of 3% of reading, least significant digit or 20 ft/min Speed | 0.1 m/s | 0.6 to 40.0 m/s |
| 1 ft/min | 118 to 7,874 ft/min | ||
| 0.1 km/h | 2.2 to 144.0 km/h | ||
| 0.1 mph | 1.3 to 89.5 mph | ||
| 0.1 knots | 1.2 to 77.8 knots | ||
| 1 B* | 0 to 12 B* | ||
| 0.1 F/S* | 2-131.2* | ||
| Ambient Temperature | 0.9 °F | 0.1 °F | -20.0 to 158.0 °F |
| 0.5 °C | 0.1 °C | -29.0 to 70.0 °C | |
| Relative Humidity | 2%RH | 0.1 %RH | 10 to 90% 25°C noncondensing |
| Pressure | 1.5 hPa|mbar | 0.1 hPa|mbar | 25°C/77°F |
| 0.044 inHg | 0.01 inHg | 700-1100 hPa|mbar | |
| 0.022 PSI | 0.01 PSI | 20.67-32.48 inHg | |
| 10.15-15.95 PSI | |||
| Compass | 5° | 1° | 0 to 360° |
| 1/16th Cardinal Scale |
| CALCULATED MEASUREMENTS | |||
|---|---|---|---|
| MEASUREMENT | ACCURACY (+/-) | RESOLUTION | SENSORS EMPLOYED |
| Air Density | 0.0002 lb/ft3 0.0033 kg/m |
0.001 lbs/ft3 0.001 kg/m3 |
Temperature, Relative Humidity Pressure |
| Air Flow | 6.71% | 1 cfm 1 m3/hr 1 m3/m 0.1m3/s 1 L/s |
Air Speed, User Input (Duct Shape & Size) |
| Altitude | typical: 23.6 ft/7.2 m from 750 to 1100 mBar max: 48.2 ft/14.7 m from 300 to 750 mBar |
1 ft 1 m | Pressure, User Input (Reference Pressure) |
| Barometric Pressure | 0.07 inHg 2.4 hPa|mbar 0.03 PSI |
0.01 inHg 0.1 hPa|mbar 0.01 PSI |
Pressure, User Input (Reference Altitude) |
| Crosswind & Headwind/Tailwind | 7.1% | 1 mph 1 ft/min 0.1 km/h 0.1 m/s 0.1 knots |
Wind Speed, Compass |
| Delta T | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C | Temperature, Relative Humidity Pressure |
| Density Altitude | 226 ft 69 m |
1 ft 1 m | Temperature, Relative Humidity Pressure |
| Dew Point | 3.4 °F 1.9 °C 15- 95% RH. Refer to Range for Temperature Sensor |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| Evaporation Rate | 0.01 lb/ft2/hr 0.06 kg/m2/hr |
0.01 b/ft2/hr 0.01 kg/m2/hr |
Wind Speed, Temperature Relative Humidity Pressure, User Input (Concrete Temperature) |
| Heat Index | 7.1°F 4.0°C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| Moisture Content | Humidity Ratio (“Grains”) | 4.9gpp .7g/kg |
0.1 gpp 0.01 g/kg |
Temperature, Relative Humidity Pressure |
| Probability of Ignition (PIG) | PIG Accuracy dependent on proximity of inputs to reference table steps. | 10% | Temperature, Relative Humidity |
| THI (NRC) | 1.5 °F 0.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| THI (Yousef) | 2.3 °F 1.3 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity |
| Relative Air Density | .0.3% | 0.1% | Temperature, Relative Humidity Pressure |
| Wet Bulb Temperature – Psychrometric | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature, Relative Humidity Pressure |
| Wet Bulb Temperature – Naturally Aspirated (NWB TEMP) | 1.4 °F 0.8 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature Globe Temperature, Relative Humidity, Pressure |
| Wind Chill | 1.6 °F 0.9 °C |
0.1 °F 0.1 °C |
Wind Speed, Temperature |
| ADDITIONAL PRODUCT INFO | |
|---|---|
| Display & Backlight | Multifunction, multidigit monochrome dot-matrix display. Choice of white or red LED backlight. |
| Response Time & Display Update | Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. WBGT requires about 8 minutes to reach 95% accuracy and about 15 minutes to reach 99% accuracy after exposure to large environmental changes. |
| Data Storage & Graphical display Min/Max/Avg History | Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours*, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points. |
| data Upload & Bluetooth Data Connect Option | Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC). |
| Clock/Calendar | Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
| Auto Shutdown | User-selectable – Off, 15-60 minutes with no key presses. |
| Languages | English, French, German, Spanish. |
| Certifications | CE certified, RoHS, FCC, IC tested and WEEE compliant. Individually tested to NIST-traceable standards. |
| Origin | Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B. |
| Battery Life | AA Lithium included. Up to 400 hours of use, reduced by backlight, alert light and buzzer, or Bluetooth radio transmission use. |
| Shock Resistance | MIL-STD-810g, Transit Shock, Method 516.6 Procedure IV; unit only; impact may damage replaceable impeller. |
| Sealing | Waterproof (IP67 and NEMA-6) |
| Display & Battery Operational Temperature Limits | 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading. |
| Storage Temperature | -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C. |
| Size & Weight | 5.0 x 1.9 x 1.1 in | 12.7 x 4.5 x 2.8 cm, 4.3 oz | 121 g. (Lithium battery included) |
Impeller:
Every Kestrel Meter features a large, 1” impeller mounted on a sapphire jewel bearing, which means it starts rotating with the slightest puff of air – 0.48 km/h to be exact! This patented impeller is user-replaceable by simply pushing it out with your thumbs, which means it can easily be replaced if it is damaged or worn. The measurements from the wind impeller are taken magnetically. The impeller is not glued or attached to the unit. Because every new impeller is calibrated in the wind tunnel at the USA factory, if your application demands regular calibration, simply pop in a new impeller and the Kestrel Wind Meter is restored to like-new factory calibration standards. The Kestrel 5000 can easily be switched between °F, °C, mph, km/h, ft/min, m/s, knots and Beaufort.
* Applies to LiNK models only